Neuroradiology
-
The purpose of this study was to determine the appropriate order of CT angiography and CT perfusion in a multimodal stroke CT protocol. ⋯ Reversal of CT stroke protocol had no significant influence on quantitative parameters of CTP. Subjective quality of extracranial venous contrast was rated to be superior when CTA was performed before CTP.