Anesthesia and analgesia
-
Anesthesia and analgesia · Sep 2011
Historical ArticleWhere we were, where we are, where we are going.
-
Anesthesia and analgesia · Sep 2011
Comparative Study Clinical TrialEvaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery.
Reliable cardiac output monitoring is particularly useful in the cirrhotic patient undergoing liver transplant surgery, because cirrhosis of the liver is associated with a vasodilated and high output state, known as cirrhotic cardiomyopathy, that challenges the reliability of pulse contour cardiac output technology. The contractility of the ventricle in cirrhosis is impaired, which is tolerated even though the ejection fraction and cardiac output are elevated because of the low peripheral resistance. However, during surgery the cirrhotic patient can decompensate because of the physiological changes and stress of surgery. Recently, we showed that the FloTrac/Vigileo™ failed to perform in cirrhotic patients undergoing transplant surgery. In response, the company upgraded their software. Therefore, we have assessed the accuracy and reliability of this new third-generation (version 3.02) FloTrac/Vigileo algorithm software in the same setting. ⋯ The new software (version 3.02) provided substantial improvements over the previous versions with better overall precision and trending ability. Further algorithm refinements will increase this technology's reliability to be extensively used in the highly complex setting of cirrhotic patients undergoing liver transplantation.
-
Anesthesia and analgesia · Sep 2011
Comparative StudyThe ability of pulse pressure variations obtained with CNAP™ device to predict fluid responsiveness in the operating room.
Respiratory-induced pulse pressure variations obtained with an arterial line (ΔPP(ART)) indicate fluid responsiveness in mechanically ventilated patients. The Infinity® CNAP™ SmartPod® (Dräger Medical AG & Co. KG, Lübeck, Germany) provides noninvasive continuous beat-to-beat arterial blood pressure measurements and a near real-time pressure waveform. We hypothesized that respiratory-induced pulse pressure variations obtained with the CNAP system (ΔPP(CNAP)) predict fluid responsiveness as well as ΔPP(ART) predicts fluid responsiveness in mechanically ventilated patients during general anesthesia. ⋯ A value of ΔPP(CNAP) >11% has a sensitivity of at least 62% in predicting preload-dependent responders to VE in mechanically ventilated patients during general anesthesia.
-
Anesthesia and analgesia · Sep 2011
Gamma-aminobutyric acid type A receptor β3 subunit forebrain-specific knockout mice are resistant to the amnestic effect of isoflurane.
β3 containing γ-aminobutyric acid type A receptors (GABA(A)-Rs) mediate behavioral end points of IV anesthetics such as immobility and hypnosis. A knockout mouse with targeted forebrain deletion of the β3 subunit of the GABA(A)-R shows reduced sensitivity to the hypnotic effect of etomidate, as measured by the loss of righting reflex. The end points of amnesia and immobility produced by an inhaled anesthetic have yet to be evaluated in this conditional knockout. ⋯ These results suggest that β3 containing GABA(A)-Rs in the forebrain contribute to hippocampal-dependent memory suppressed by isoflurane, but not etomidate.