Anesthesia and analgesia
-
Anesthesia and analgesia · Jan 2016
Randomized Controlled Trial Multicenter StudyA Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial.
Closed-loop systems for anesthesia delivery have been shown to outperform traditional manual control in different clinical settings. The present trial was aimed at evaluating the feasibility and efficacy of Bispectral Index (BIS)-guided closed-loop anesthesia delivery system (CLADS) in comparison with manual control across multiple centers in India. ⋯ Our study in a multicenter setting proves the consistently better performance of automated anesthesia drug delivery compared with conventional manual control. This highlights an important advantage of an automated system for delivering standardized anesthesia, thereby overcoming differences in practices among anesthesiologists.
-
Anesthesia and analgesia · Jan 2016
Randomized Controlled Trial Multicenter Study Comparative StudyUltrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.
Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. ⋯ We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.
-
Anesthesia and analgesia · Jan 2016
Randomized Controlled TrialPerioperative Duloxetine to Improve Postoperative Recovery After Abdominal Hysterectomy: A Prospective, Randomized, Double-Blinded, Placebo-Controlled Study.
Postsurgical quality of recovery is worse in female than that in male patients. Duloxetine has been used successfully for the treatment of chronic pain conditions, but its use for preventing acute postoperative pain has been limited to a single previous study. More importantly, the effect of preoperative duloxetine on global postoperative quality of recovery has yet to be evaluated. The main objective of the current investigation was to evaluate the effect of perioperative duloxetine on postoperative quality of recovery in women undergoing abdominal hysterectomy. ⋯ Duloxetine improves postoperative quality of recovery after abdominal hysterectomy. In addition, duloxetine reduces postoperative opioid consumption, even in the presence of a robust multimodal analgesic strategy. Duloxetine seems to be a viable pharmacologic strategy to improve postoperative quality of recovery in female patients undergoing abdominal hysterectomy.
-
Anesthesia and analgesia · Jan 2016
ReviewEfficacy Outcome Measures for Procedural Sedation Clinical Trials in Adults: An ACTTION Systematic Review.
Successful procedural sedation represents a spectrum of patient- and clinician-related goals. The absence of a gold-standard measure of the efficacy of procedural sedation has led to a variety of outcomes being used in clinical trials, with the consequent lack of consistency among measures, making comparisons among trials and meta-analyses challenging. We evaluated which existing measures have undergone psychometric analysis in a procedural sedation setting and whether the validity of any of these measures support their use across the range of procedures for which sedation is indicated. ⋯ Certain scales, for example, those requiring motor stimulation, are unsuitable to evaluate sedation for procedures where movement is prohibited (e.g., magnetic resonance imaging scans). Further work is required to evaluate existing measures for procedures for which they were not developed. Depending on the outcomes of these efforts, it might ultimately be necessary to consider measures of sedation efficacy to be procedure specific.