Der Chirurg; Zeitschrift für alle Gebiete der operativen Medizen
-
Distal interlocking of intramedullary nails is associated with a relatively high radiation exposure. For the reduction of fluoroscopy time and surgeon's hands irradiation, many devices have been developed so far. In this paper, a simple free-hand-technique is presented. ⋯ A centrally perforated 4.5 mm drill is placed over the K-wire. Therefore in this technique a perfect centrally placement of the K-wire is not necessary. The drill is guided by the K-wire thereby avoiding complications such as drill failure or deviation of the drill direction.