Epilepsia
-
Thirty-two neonates (26 term and 6 premature) having seizures were prospectively recruited and studied. Using prolonged video/EEG monitoring, we quantified seizure variables (electrographic and clinical seizure durations, interictal periods and electrographic seizure spread) for all 1,420 seizures recorded. The effects of time and antiepileptic drug (AED) therapy were analyzed statistically. ⋯ Among neonates with clear clinical correlates, clinical observations underestimated electrographic seizures in individual neonates by a mean of 54% (range 0-95%). Seizures generally had limited electrographic spread. Use of only four recording electrodes, characteristic of some portable EEG systems, underestimated seizures in 19 neonates, and missed all seizures in 2.