Medicine
-
Review Case Reports
Sudden death after endoscopic retrograde cholangiopancreatography (ERCP)--case report and literature review.
There are only a few cases found in literature regarding air embolism in endoscopic procedures, especially in connection to endoscopic retrograde cholangiopancreatography (ERCP). We are presenting a case of a 56-year-old female patient who suffered from non-Hodgkin lymphoma located in her right groin. She was also diagnosed with choledocholithiasis and underwent ERCP to remove the gallstones. ⋯ We reviewed literature in order to identify possible causes of death because fatal outcome following an uneventful and successful procedure was not expected. It is important to bear in mind all possible complications of ERCP. Our focus during the literature search was on air embolism.
-
Multicenter Study
BRAFV600E immunopositive melanomas show low frequency of heterogeneity and association with epithelioid tumor cells: a STROBE-compliant article.
Treatment of BRAFV600E-mutant melanoma by small molecule inhibitors that target BRAFV600E or MEK kinases is increasingly used in clinical practice and significantly improve patient outcome. However, patients eventually become resistant and therapeutic improvement is required. Molecular diversity within individual tumors (intratumor heterogeneity) and between tumors within a single patient (intrapatient heterogeneity) poses a significant challenge to precision medicine. ⋯ The primary tumor was also morphologically heterogeneous and exclusively displayed BRAFV600E in the epithelioid component, confirming an association between BRAFV600E and epithelioid cells. Twenty-eight of 30 patients (93%) had concordant BRAFV600E mutation status between their tumors. Taken together, BRAFV600E intratumor and intrapatient heterogeneity in melanoma is diminutive, nevertheless, the identified exceptions will have important implications for the clinical management of this disease.
-
There are numerous reports of treatment methods for spondylolisthesis with a Meyerding Grade of more than III. In high dysplastic spondylosthesis, surgical treatment was selected because there is considered to be a high possibility of low back pain and lower limb neurological symptoms worsening if slippage progresses. Monosegmental lumbar interbody fusion (L5-S1) with a pedicle screw system (PPS) was used to treat three cases of Meyerding Grade IV developmental spondylolisthesis. ⋯ However, in one case with little spinal mobility due to vertebral body dysplasia, despite performing sufficient decompression of the nerve root at L5 and slow reduction to avoid placing excessive tension on the nerve root, a transient neurological disorder was observed. A PPS was used to increase the reduction strength and favorable reduction was possible. However, in the case with a long clinical course and the case with poor spinal mobility, since the mobility and plasticity of the nerve root itself may have been reduced, it was considered that reduction should be performed carefully using intraoperative neurological monitoring.
-
Observational Study
Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.
This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. ⋯ There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval -3.5 to -2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.
-
Recent biomechanics studies have revealed distinct kinematic behavior of different lumbar segments. The mechanisms behind these segment-specific biomechanical features are unknown. This study investigated the in vivo geometric characteristics of human lumbar intervertebral discs. ⋯ Although the lengths of the lower lumbar discs were similar, the geometry of the AF and NP showed segment-dependent properties. These data may provide insight into the understanding of segment-specific biomechanics in the lower lumbar spine. The data could also provide baseline knowledge for the development of segment-specific surgical treatments of lumbar diseases.