Journal of clinical microbiology
-
J. Clin. Microbiol. · Apr 2009
Evaluation of phenotypic tests for detection of metallo-beta-lactamase-producing Pseudomonas aeruginosa strains in China.
A total of 264 nonduplicate strains of imipenem (IPM)-nonsusceptible Pseudomonas aeruginosa were isolated from hospitals in 16 different regions throughout China. These 264 IPM-nonsusceptible clinical isolates of P. aeruginosa were examined by PCR, a metallo-beta-lactamase (MBL) Etest, a double-disk synergy test (DDST), and a test using combined IPM disks supplemented with various amounts of EDTA. A total of 24 strains positive for MBLs were confirmed by PCR and DNA sequence analysis: 10 strains positive for the bla(VIM-2) gene, 13 strains positive for the bla(IMP-9) gene, and 1 strain positive for the bla(IMP-1) gene. ⋯ The sensitivities, specificities, and positive and negative predictive values for the MBL Etest, the DDST, and the combined disk (CD) assay were evaluated. The best method for screening for MBL production in P. aeruginosa strains from China was the CD assay (IMP-EDTA) using 750 microg of EDTA/disk with a breakpoint of >or=6 mm. In the CD assay (IPM-EDTA) with 290 microg and 750 microg EDTA, the zone diameter increases for VIM-2-producing P. aeruginosa isolates were greater than those for IMP-9-producing P. aeruginosa isolates (P = 0.00).
-
J. Clin. Microbiol. · Apr 2009
Impact of blood cultures drawn by phlebotomy on contamination rates and health care costs in a hospital emergency department.
We conducted a prospective comparison of blood culture contamination rates associated with dedicated phlebotomists and nonphlebotomy staff in the emergency department (ED) at Parkland Memorial Hospital in Dallas, TX. In addition, hospital charges and lengths of stay were determined for patients with negative, false-positive, and true-positive blood culture results. A total of 5,432 blood culture collections from two ED areas, the western wing of the ED (ED west) and the nonwestern wing of the ED (ED nonwest), were evaluated over a 13-month period. ⋯ Similar results were observed when rates between phlebotomists in ED west and nonphlebotomy staff in ED nonwest were compared (62/2,012 [3.1%] versus 100/1,770 [5.6%]; P < 0.001). Comparison of median patient charges between negative and false-positive episodes ($18,752 versus $27,472) showed $8,720 in additional charges per contamination event while the median length of stay increased marginally from 4 to 5 days. By utilizing phlebotomists to collect blood cultures in the ED, contamination rates were lowered to recommended levels, with projected reductions in patient charges of approximately $4.1 million per year.