Journal of clinical microbiology
-
J. Clin. Microbiol. · Aug 2021
Implementation of SARS-CoV2 Screening in K-12 Schools Using In-School Pooled Molecular Testing and Deconvolution by Rapid Antigen Test.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) testing is one component of a multilayered mitigation strategy to enable safe in-person school attendance for the K-12 school population. However, costs, logistics, and uncertainty about effectiveness are potential barriers to implementation. We assessed early data from the Massachusetts K-12 public school pooled SARS-CoV2 testing program, which incorporates two novel design elements: in-school "pod pooling" for assembling pools of dry anterior nasal swabs from 5 to 10 individuals and positive pool deconvolution using the BinaxNOW antigen rapid diagnostic test (Ag RDT), to assess the operational and analytical feasibility of this approach. ⋯ However, of 124 positive pools with full reflex testing data available for analysis, 32 (25.8%) of BinaxNOW pool deconvolution testing attempts did not identify a positive individual, requiring additional reflex testing. With sufficient staffing support and low pool positivity rates, pooled sample collection and reflex testing were feasible for schools. These early program findings confirm that screening for K-12 students and staff is achievable at scale with a scheme that incorporates in-school pooling, primary testing by reverse transcription-PCR (RT-PCR), and Ag RDT reflex/deconvolution testing.
-
J. Clin. Microbiol. · Aug 2021
Assessing the quality of serological testing in the CoViD-19 pandemic: results of a European external quality assessment (EQA) scheme for anti-SARS-CoV-2 antibody detection.
External quality assessment (EQA) is a key instrument for achieving harmonization, and thus a high quality, of diagnostic procedures. As reliable test results are crucial for accurate assessment of SARS-CoV-2 infection prevalence, vaccine response, and immunity, and thus for successful management of the ongoing COVID-19 pandemic, the Reference Institute for Bioanalytics (RfB) was the first EQA provider to offer an open scheme for anti-SARS-CoV-2 antibody detection. The main objectives of this EQA were (i) to gain insights into the current diagnostic landscape and the performance of serological tests in Europe and (ii) to provide recommendations for diagnostic improvements. ⋯ For cutoff samples, a drop in the diagnostic sensitivity to 46.3% and high interlaboratory variability were observed. In general, this EQA highlights the current variability of anti-SARS-CoV-2 antibody detection, technical limitations with respect to cutoff samples, and the lack of harmonization of testing procedures. Recommendations are provided to help laboratories and manufacturers further improve the quality of anti-SARS-CoV-2 serological diagnostics.