Proceedings of the National Academy of Sciences of the United States of America
-
Proc. Natl. Acad. Sci. U.S.A. · Feb 2018
Assessment of the Legionnaires' disease outbreak in Flint, Michigan.
The 2014-2015 Legionnaires' disease (LD) outbreak in Genesee County, MI, and the outbreak resolution in 2016 coincided with changes in the source of drinking water to Flint's municipal water system. Following the switch in water supply from Detroit to Flint River water, the odds of a Flint resident presenting with LD increased 6.3-fold (95% CI: 2.5, 14.0). This risk subsided following boil water advisories, likely due to residents avoiding water, and returned to historically normal levels with the switch back in water supply. ⋯ During the switch, the risk of a Flint neighborhood having a case of LD increased by 80% per 1 mg/L decrease in free chlorine, as calculated from the extensive variation in chlorine observed. In communities adjacent to Flint, the probability of LD occurring increased with the flow of commuters into Flint. Together, the results support the hypothesis that a system-wide proliferation of legionellae was responsible for the LD outbreak in Genesee County, MI.