The New England journal of medicine
-
Multicenter Study Clinical Trial
Multidetector-row computed tomography in suspected pulmonary embolism.
Single-detector-row computed tomography (CT) has a low sensitivity for pulmonary embolism and must be combined with venous-compression ultrasonography of the lower limbs. We evaluated whether the use of D-dimer measurement and multidetector-row CT, without lower-limb ultrasonography, might safely rule out pulmonary embolism. ⋯ Our data indicate the potential clinical use of a diagnostic strategy for ruling out pulmonary embolism on the basis of D-dimer testing and multidetector-row CT without lower-limb ultrasonography. A larger outcome study is needed before this approach can be adopted.