The New England journal of medicine
-
Randomized Controlled Trial Multicenter Study
Effectiveness of Fluticasone Furoate-Vilanterol for COPD in Clinical Practice.
Background Evidence for the management of chronic obstructive pulmonary disease (COPD) comes from closely monitored efficacy trials involving groups of patients who were selected on the basis of restricted entry criteria. There is a need for randomized trials to be conducted in conditions that are closer to usual clinical practice. Methods In a controlled effectiveness trial conducted in 75 general practices, we randomly assigned 2799 patients with COPD to a once-daily inhaled combination of fluticasone furoate at a dose of 100 μg and vilanterol at a dose of 25 μg (the fluticasone furoate-vilanterol group) or to usual care (the usual-care group). ⋯ There were no excess serious adverse events of pneumonia in the fluticasone furoate-vilanterol group. The numbers of other serious adverse events were similar in the two groups. Conclusions In patients with COPD and a history of exacerbations, a once-daily treatment regimen of combined fluticasone furoate and vilanterol was associated with a lower rate of exacerbations than usual care, without a greater risk of serious adverse events. (Funded by GlaxoSmithKline; Salford Lung Study ClinicalTrials.gov number, NCT01551758 .).
-
Randomized Controlled Trial Multicenter Study
Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure.
Background The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). ⋯ Sudden cardiac death occurred in 24 patients (4.3%) in the ICD group and in 46 patients (8.2%) in the control group (hazard ratio, 0.50; 95% CI, 0.31 to 0.82; P=0.005). Device infection occurred in 27 patients (4.9%) in the ICD group and in 20 patients (3.6%) in the control group (P=0.29). Conclusions In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic and others; DANISH ClinicalTrials.gov number, NCT00542945 .).