International journal of radiation oncology, biology, physics
-
Int. J. Radiat. Oncol. Biol. Phys. · Mar 2007
Review Comparative StudyClinical implications of defining the gross tumor volume with combination of CT and 18FDG-positron emission tomography in non-small-cell lung cancer.
To compare the planning target volume (PTV) definitions for computed tomography (CT) vs. positron emission tomography (PET) in non-small-cell lung cancer (NSCLC). ⋯ Computed tomography and PET are complementary and should be obtained in the treatment position and fused to define the GTV for NSCLC. Although the quantitative absolute target volume is sometimes similar, the qualitative target locations can be substantially different, leading to underdosage of the target when planning is done using CT alone without PET fusion.