The Journal of hand surgery
-
Controversy exists surrounding the effectiveness and complications associated with dorsal plating for distal radius fractures. This study evaluated the functional outcome of dorsal plating for dorsally angulated distal radius fractures at a single institution. ⋯ Results from this study show that patients can expect to have 80% of their range of motion and strength after dorsal plating for distal radius fractures. Moreover, 93% of the patients will have good to excellent functional outcomes. Complications from dorsal plating may be caused by the specific plate used, rather than by the technique itself, supporting a dorsal approach for dorsally angulated distal radius fractures.
-
To investigate the clinical outcome of thumb carpometacarpal arthroplasty with entire-thickness flexor carpi radialis (FCR) ligament reconstruction and tendon interposition and to investigate the isokinetic wrist flexion/extension torque and flexion fatigue strength of the surgically treated wrist compared with the nonsurgically treated wrist. ⋯ Our data show conclusively that wrist flexion extension torque ratio decreases and wrist flexion fatigue resistance decreases when the entire FCR tendon is harvested even though the final outcome is favorable and uniformly based on traditional DASH, grip, and pinch scores.
-
To apply carpal kinematic analysis using noninvasive medical imaging to investigate the midcarpal and radiocarpal contributions to wrist flexion and extension in a quasidynamic in vitro model. ⋯ The capitate and scaphoid tend to move together. This results in greater flexion/extension for the scaphoid than the lunate at the radiocarpal joint. The lunate has greater midcarpal motion between it and the capitate than the scaphoid does with the capitate. The engagement between the scaphoid and capitate is particularly evident during wrist extension. Out-of-plane motion was primarily ulnar deviation at the radiocarpal joint during flexion. These results are clinically useful in understanding the consequences of isolated fusions in the treatment of wrist instability.
-
The current trend is to treat distal radius fractures with open reduction and internal fixation with either titanium or stainless steel plates. Both provide stable fixation; however, there is minimal evidence concerning the soft-tissue response to these materials. Our objective was to evaluate the response of adjacent extensor tendons to titanium and stainless steel in a rabbit in vivo model and to evaluate the influence of time. ⋯ Our results indicate that both implants generated adjacent reactive inflammatory tissue and particulate debris. There was no difference in cell or particle number produced by both materials. There is a statistically significant increase in inflammatory cells with increasing time of implantation.