Lung
-
To investigate the influence of nasal continuous positive airway pressure (CPAP) on apnea-related desaturation, we compared the sleep apnea-related desaturations obtained during a polysomnographic study before and during nasal CPAP in 15 sleep apnea patients. An individual desaturation curve was determined with a regression analysis by plotting the lowest SaO2 value reached during each apnea against its duration; these data were collected throughout the night. At baseline, we only considered the apneas with a preapneic SaO2 value greater than 90% and a minimal SaO2 value above or equal to 60%. ⋯ The preapneic SaO2 value was 94.8 +/- 0.3% at baseline and 95.5 +/- 0.2% during CPAP (p = 0.5). The desaturation area decreased from 267 +/- 48% SaO2/sec at baseline to 152 +/- 41% SaO2/sec during CPAP (p less than 0.001). We conclude that CPAP improves the apnea-related desaturation independently of the shortening of apneas and of any difference in the preapneic SaO2 value.