Intensive care medicine
-
Intensive care medicine · May 1980
Hemodynamics and renal function during low frequency positive pressure ventilation with extracorporeal CO2 removal. A comparison with continuous positive pressure ventilation.
Six lambs were anesthetized and connected venovenous mode to a Membrane Lung for Extracorporeal CO2 removal. The animals underwent several hours periods of continuous positive pressure ventilation (CPPV), at 5 cmH2O positive end expiratory pressure (PEEP), alternated with several hours periods of low frequency positive pressure ventilation (5 cmH2O PEEP, 2 b.p.m.) with extracorporeal CO2 removal (LFPPV-ECCO2R). ⋯ The renal function improved significantly during LFPPV-ECCO2R compared with CPPV, i.e. urinary flow, creatinine clearance and osmolar clearance increased by 50%, 37% and 52% respectively. In these experiments LFPPV-ECCO2R, a form of completely artificial ventilation, seems to prevent hemodynamic and renal complications of CPPV.