Evaluation of buprenorphine LUCIO immunoassay versus GC-MS using urines from a workplace drug testing program.
The buprenorphine (BUP) LUCIO Nal Von Minden screening assay was evaluated. Urine samples from subjects enrolled in a workplace drug testing program were screened according to the manufacturer's instruction using a Roche COBAS Integra 800 analyser. For gas chromatography-mass spectrometry (GC-MS) confirmatory analysis, samples were submitted to enzymatic hydrolysis with β-glucuronidase and mixed-mode solid-phase extraction. ⋯ At the 5 ng/mL cut-off, the immunoassay showed 100% sensitivity and 88% specificity, with an overall agreement of 94% between immunoassay and GC-MS. Raising the cut-off to 10 ng/mL provided an identical overall agreement between immunoassay and GC-MS (94%), despite the decrease in sensitivity (90%) and the increase in specificity (100%). According to these results, the BUP LUCIO Nal Von Minden screening assay provides adequate sensitivity and specificity for BUP screening in urine samples using a cut-off concentration of 5 ng/mL.
-
A sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method has been developed and validated for the quantification of buprenorphine, fentanyl and lysergic acid diethylamide (LSD) in whole blood. Sample preparation was performed by liquid-liquid extraction (LLE) with methyl tert-butyl ether. UPLC-MS-MS analysis was performed with a mobile phase consisting of ammonium formate (pH 10.2) and methanol. ⋯ Most phospholipids were removed during LLE. No or only minor matrix effects were observed. The method has been routinely used at the Norwegian Institute of Public Health since September 2011 for qualitative and quantitative detections of buprenorphine, fentanyl and/or LSD in more than 400 whole blood samples with two replicates per sample.
-
Pethidine (meperidine), a synthetic opiate, formally used as an analgesic in surgery and obstetrics, has been an abused drug of choice for some doctors. A case is presented in which a doctor, who previously admitted to using pethidine, was suspected of re-using, following a second positive urine test. A laboratory had reported the presence of pethidine in the doctor's urine; however, the doctor denied re-use. ⋯ Urine samples from a patient receiving pethidine for pain, from the previous pethidine use of the doctor, and the urine under question plus the control were analyzed for the presence of pethidinic acid using electrospray mass spectrometry. Pethidinic acid was found in all samples except the one under dispute. The absence of pethidinic acid appeared to corroborate the doctor's denial of re-use.
-
3,4-Methylenedioxypyrovalerone (MDPV) is a psychoactive, synthetic analog of the central nervous system stimulant cathinone. Its recent popularity as a recreational drug in the United States has led to numerous reports to poison control centers across the country. As with other synthetic cathinones, the recreational use of MDPV has resulted in death. ⋯ Tissue and fluids responsible for detoxification/excretion had higher concentrations of MDPV (kidney, liver and bile > 0.8 µg/mL). A blood concentration ≥ 0.4 µg/mL was judged sufficient to cause death. The cause of death was ruled MDPV intoxication resulting in cardiac arrhythmia.
-
To date, the Toxicology Section of the Montgomery County Coroner's Office/Miami Valley Regional Crime Laboratory has identified six synthetic cathinones, commonly found in bath salt products, in 43 cases. Thirty-two cases will be reviewed here, including all of the postmortem cases, all of the human performance cases that had blood specimens submitted, and one urine-only human performance case. The following compounds have been confirmed: 3,4-methylenedioxypyrovalerone (MDPV), 3,4-methylenedioxymethcathinone (methylone), pyrovalerone, pentylone, alpha-pyrrolidinopentiophenone (alpha-PVP) and methedrone. ⋯ After review, blood concentration does not appear to predict outcome regarding fatalities or impairment. The highest MDPV concentration occurred in a suicide by hanging and the highest methylone concentration was in a driver. The confirmation method is a liquid-liquid extraction with detection by liquid chromatography triple quadrupole mass spectrometry using electrospray ionization in multiple reaction monitoring mode.