Artificial organs
-
Multicenter Study Comparative Study
Substitution of acetic acid for hydrochloric acid in the bicarbonate buffered dialysate.
In a multicenter study including 5 dialysis units, blood acetate changes during 4 h dialysis sessions in 141 patients treated with a 4 mM acetate-containing bicarbonate dialysate (ABD) were evaluated and compared to the values of 114 patients using an acetate-free bicarbonate dialysate (AFD). Acetate-free bicarbonate dialysate was delivered by a dialysis machine from the mixing with water for dialysis of a 1/26.2 bicarbonate concentrate, and a 1/35 acid-concentrate in which acetic acid was substituted for hydrochloric acid (Soludia, Fourquevaux, France). This new type of dialysate was routinely in use for 3 years on average (range, from 2 to 5 years). ⋯ Hyperacetatemia was controlled with AFD in patients whose predialysis acetate plasma concentration of 316+/-82 decreased to 55 +/-23 microM (n = 6) at the end of the dialysis session whereas the acetate plasma concentration remained high when the predialysis concentration was 580+/-76 microM, with a postdialysis concentration of 233+/-39 microM (n = 28). It is concluded that in patients whose predialysis blood acetate levels were in the physiologic range, acetate-containing bicarbonate dialysate induces hyperacetatemia whereas postdialysis blood acetate remains in the normal range in such dialysis patients treated with acetate-free dialysate. Chronic hyperacetatemia, which could be found in dialysis patients, is well controlled by dialysis using an acetate-free dialysate.