This article summarizes the use of computational fluid dynamics (CFD) to design a novel suspended Tesla left ventricular assist device. Several design variants were analyzed to study the parameters affecting device performance. CFD was performed at pump speeds of 6500, 6750, and 7000 rpm and at flow rates varying from 3 to 7 liters per minute (LPM). ⋯ To assess the device hemodynamics the strain rate fields were evaluated. The wall shear stresses demonstrated that the pump wall shear stresses were likely adequate to inhibit thrombus deposition. Finally, an integrated field hemolysis model was applied to the CFD results to assess the effects of design variation and operating conditions on the device hemolytic performance.
-
Pediatric patients with end-stage heart failure require mechanical circulatory support (MCS) just as adults do. In order to meet the special requirements for neonates' and infants' MCS, pediatric circulatory support devices must be compact with low priming volume, easily controllable with low flow, less traumatic for blood cells and tissues, and biocompatible with minimum anticoagulation. We have designed and developed a miniature rotary centrifugal blood pump, "TinyPump," with a priming volume of 5 mL, which has already demonstrated its controllable performance for low flow and durability in vitro. ⋯ In the early experiments, hemolysis and thrombi formation at the impeller bearing resulted in termination of the study. Subsequent modifications of the bearing design, pump housing design, and magnetic coupling force helped to minimize the hemolysis and thrombi formation, prolonging the survival duration of the Shiba goats to 2 weeks with minimum adverse effects on the blood components and organ functions. With further experiments and improvements in pump durability and hemocompatibility, the TinyPump can serve as a suitable circulatory support device for neonates and infants bridging to heart transplantation as well as to heart recovery.
-
The insults sustained by transplanted livers (hepatectomy, hypothermic preservation, and normothermic reperfusion) could compromise hepatic function. Hydrogen sulfide (H₂S) is a physiologic gaseous signaling molecule, like nitric oxide (NO) and carbon monoxide (CO). We examined the effect of diallyl disulfide as a H₂S donor during hypothermic preservation and reperfusion on intrahepatic resistance (IVR), lactate dehydrogenase (LDH) release, bile production, oxygen consumption, bromosulfophthalein (BSP) depuration and histology in an isolated perfused rat liver model (IPRL), after 48 h of hypothermic storage (4 °C) in University of Wisconsin solution (UW, Viaspan). ⋯ Hepatic clearance (HC) of BSP was affected by cold storage of livers, but there were no noticeable differences between livers preserved with or without diallyl disulfide. Meanwhile, livers preserved in the presence of H₂S donor showed an enhanced capacity for BSP uptake (k(A) CON = 0.29 min⁻¹; k(A) UW = 0.29 min⁻¹ ; k(A) UWS = 0.36 min ⁻¹). In summary, our animal model suggests that hepatic hypothermic preservation for transplantation affects liver function and hepatic depuration of BSP, and implies that the inclusion of an H₂S donor during hypothermic preservation could improve standard methods of preparing livers for transplant.