Artificial organs
-
This study investigated the efficacy of prophylactic intraoperative intra-aortic balloon pump (IABP) usage in chronic heart failure patients with severely reduced left ventricular function undergoing elective cardiac surgery. Between January 2008 and December 2012, 107 patients with severely reduced left ventricular ejection fraction (LVEF <35%) received prophylactic intraoperative IABP implantation during open-heart surgery. Surgical procedures performed were isolated coronary artery bypass grafting (CABG) in 35 patients (32.7%), aortic valve replacement in 12 (11.2%), mitral valve repair or replacement in 15 (14.0%), combined valve and CABG procedures in 27 (25.2%), and other surgical procedures in 18 (16.8%). ⋯ Mean durations of ICU and hospital stay were 3.38 ± 2.15 days and 7.69 ± 2.02 days, respectively, in the IABP group, and 4.20 ± 3.14 days and 8.57 ± 3.26 days in the control group, showing statistically significant reductions in duration of ICU and hospital stay in the IABP group (ICU stay, P = 0.036; hospital stay, P = 0.015). Thirty-day survival rates were 92.5 and 94.4% in the IABP and control group, respectively, showing no statistically significant difference (P = 0.75). IABP usage in chronic heart failure patients with severely reduced LVEF undergoing cardiac surgery was safe and resulted in shorter ICU and hospital stay but did not influence 7- and 30-day survival rates.
-
Comparative Study
Platelet function during cardiopulmonary bypass using multiple electrode aggregometry: comparison of centrifugal and roller pumps.
Blood trauma may be lower with centrifugal pumps (CPs) than with roller pumps (RPs) during cardiopulmonary bypass (CPB), because, unlike RPs, CPs do not compress the tubing, and shear stress is considered lower in CPs than in RPs. However, relative platelet function remains unclear. Using multiple electrode aggregometry (MEA), we compared platelet function with CP and RP. ⋯ Platelet function, evaluated with MEA, was lowest 30 min after CPB was started but did not decrease over time in either group. As assessed by MEA, platelet function using CP and RP did not differ significantly. Platelet dysfunction was caused mainly by initial contact with foreign materials and may not be dependent on type of pump.
-
Extracorporeal membrane oxygenation (ECMO) is a temporary mechanical circulatory assist method that offers circulatory as well as respiratory support efficiently via peripheral access; however, it is liable to complications. Limb ischemia is one of the notorious complications of ECMO but can be avoided utilizing a proper distal limb perfusion method. A retrospective study of patients undergoing peripheral venoarterial (VA) ECMO for various reasons between June 2010 and December 2012 was performed. ⋯ The mean cannula size was significantly greater than the mean introducer sheath size (11.1 ± 1.3 vs. 7.0 ± 1.1 Fr). Use of a distal-perfusion cannula is a most reliable method of limb perfusion in peripheral VA-ECMO. The cannula can ensure adequate and smooth perfusion of the limb owing to its large caliber, its less turbulent flow, the ability it provides to monitor the flow, and the option to attach a side port.