Artificial organs
-
This study aims to investigate differences in hemodynamic conditions in the thoracic aorta for pulsatile and continuous-flow left ventricular assist devices (LVADs) using computational fluid dynamics (CFD). Patient-specific models were reconstructed from three patients with continuous-flow LVAD (HeartMate II, Thoratec Corporation) and three patients with biventricular assist devices (Excor, Berlin Heart) where only the aortic part was included in the simulations. CFD simulations were performed with constant inflow for the continuous-flow LVADs and time-varying inflow for the pulsatile devices. ⋯ Elevated WSS contralaterally to the anastomosis site was observed in three of the six models with higher values for the continuous cases. Lower WSS and reduced pressure in the ascending aorta, both favorable hemodynamic conditions, were found in pulsatile versus continuous-flow LVADs by means of CFD. These findings indicate, along with clinical observations reported by others, the superior performance of pulsatile LVADs.
-
Acute kidney injury (AKI) after cardiac operations is a serious complication associated with postoperative mortality. Multiple factors contribute to AKI development, principally ischemia-reperfusion injury and inflammatory response. It is well proven that glucocorticoid administration, leukocyte filter application, and miniaturized extracorporeal circuits (MECC) modulate inflammatory response. ⋯ Not all cardiopulmonary bypass-related anti-inflammatory strategies analyzed reduced renal damage after cardiac operations. In adult patients, probably other factors are predominant on inflammation in determining AKI, and only leukocyte filters were effective. Large multicenter RCTs are needed in order to better evaluate the role of inflammation in AKI development after cardiac operations.
-
Observational Study
Extracorporeal detoxification for hepatic failure using molecular adsorbent recirculating system: depurative efficiency and clinical results in a long-term follow-up.
Acute liver failure and acute-on-chronic liver failure still show a poor prognosis. The molecular adsorbent recirculating system (MARS) has been extensively used as the most promising detoxifying therapy for patients with these conditions. Sixty-four patients with life-threatening liver failure were selected, and 269 MARS treatments were carried out as a bridge for orthotopic liver transplantation (OLT) or for liver function recovery. ⋯ In conclusion, MARS was clinically well tolerated by all patients and significantly reduced hepatic toxins. Better survival rates were linked to an OLT program, but patients' clinical characteristics on starting MARS therapy were the main factors predicting survival. The role of HGF should be evaluated in larger clinical trials.