Artificial organs
-
The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with severe biventricular heart failure underwent Berlin Heart Excor implantation with (CS status, n = 20, 50%) or without (control, n = 20, 50%) the need for preoperative ECLS as a bridge to long-term device from March 2007 to May 2015 at our institution. Demographics and preoperative baseline characteristics as well as early and long-term outcomes including mortality and complication rates were retrospectively compared between the two groups. ⋯ The proportion of patients who were bridged to transplantation was statistically similar between the ECLS and the control groups (40 vs. 52.6%, P = 0.429). Furthermore, there were no statistically significant differences in terms of early (Breslow [generalized Wilcoxon] P = 0.907) and long-term (log-rank [Mantel-Cox] P = 0.787) overall cumulative survival accounting for 30-day survival of 75 versus 75%, 6-month survival of 60 versus 55%, 1-year survival of 54 versus 40%, and 7-year survial of 47 versus 40% in the control and ECLS groups, respectively. ECLS in critical CS as a bridge to implantation of the Berlin Heart Excor ventricular assist device is safe and is associated with improvement in end-organ function leading to similar excellent early and long-term survival and incidences of major complications as in patients without the need for preoperative ECLS support.