Current guidelines recommend that all implanted pacemakers (PPM) and defibrillators (ICD) be interrogated before and after every invasive procedure. The ability of newer devices to withstand system malfunction or failure during surgery/endoscopy remains unknown. ⋯ EMIs during noncardiac surgical/endoscopic procedures pose little threat to current device systems. Rare occasions of inappropriate sensing by devices can be seen in situations where the application of unipolar electrocautery is in close proximity of the system. Routine postsurgical interrogation of PPM or ICDs may not be necessary.
-
An insertable loop recorder (ILR) in patients with infrequent syncope or palpitations may be useful to decide management strategies, including clinical observation, medical therapy, pacemaker, or implantable cardioverter defibrillator (ICD). We sought to determine the diagnostic utility of the Reveal ILR (Medtronic, Inc., Minneapolis, MN, USA) in pediatric patients. ⋯ The ILR in pediatrics is a useful adjunct to other diagnostic studies. Patient selection is critical as the ILR should not be utilized for malignant arrhythmias. A diagnosis is attained in the majority of symptomatic patients, predominantly bradyarrhythmias including pauses and intermittent AV block.
-
Pacing Clin Electrophysiol · Mar 2008
Case ReportsPercutaneous permanent pacemaker implantation via the azygous vein in a patient with superior vena cava occlusion.
Occlusion of the superior vena cava (SVCO) makes implantation of permanent pacemakers challenging and difficult. We describe an extended application of a Medtronic Attain (Medtronic Inc., Minneapolis, MN, USA) guide catheter (a tool designed for delivery of left ventricular pacing leads into the coronary sinus) for delivery of a right ventricular pacing lead via the azygous vein in a 72-year-old woman with SVCO secondary to long-term central venous hemodialysis catheters. This approach allowed the use of an endocardial pacing lead, implantation under local anesthesia, and conventional positioning of the pacemaker generator in the pectoral region in a patient with SVCO.
-
Pacing Clin Electrophysiol · Mar 2008
Defibrillation coil reversal: a rare cause of abnormal noise and inappropriate shocks.
We report a rare case of inadvertent reversal of the defibrillator shock coils during generator change which then resulted in both intermittent, recurrent "noise" on both the rate sensing and the shock electrogram leads and multiple inappropriate shocks.