Pacing and clinical electrophysiology : PACE
-
Pacing Clin Electrophysiol · Jan 2011
Case ReportsLaser extraction of a trapped infected port catheter in a child using existing experience from pacemaker and ICD lead removal.
A 9-year-old girl presented with systemic infection related to a Port-a-Cath system (PAC); therefore, the urgent removal of the PAC was indicated. However, the catheter was trapped and not extractable by conventional means. Using existing comprehensive experience in the removal of pacemaker and implantable cardioverter defibrillator leads, the entrapped PAC was successfully extracted by laser technique, thus avoiding open heart surgery.