International journal of pharmaceutics
-
Heparin employed in extracorporeal blood circulation (ECBC) procedures (e.g. open heart operations) often leads to a high incidence of bleeding complications. Protamine employed in heparin neutralization, on the other hand, can cause severe adverse reactions. We previously developed an approach that could prevent both heparin- and protamine-induced toxic side effects concomitantly. ⋯ Preliminary observations indicated that a four- to five-fold enhancement in heparin adsorption was attained by utilizing each of these new approaches. Aside from their current use, these new strategies can also be employed generically to improve the functionality of any affinity-type bioreactor. Indeed, efforts have been made recently in utilizing these approaches to develop a clinically usable GPIIb/IIIa bioreactor for the treatment of immune thrombocytopenic purpura (ITP)-an autoimmune disease.