Annals of plastic surgery
-
Annals of plastic surgery · Oct 2006
Skin regeneration for children with burn scar contracture using autologous cultured dermal substitutes and superthin auto-skin grafts: preliminary clinical study.
We have evaluated a novel treatment of burn scar contracture in children. This method involves the application of an autologous cultured dermal substitute (CDS), followed by a graft of superthin split-thickness skin. In the first operation, the autologous CDS was applied to the skin defect that had occurred after releasing the scar contracture. ⋯ However, these skin grafts were stretched gradually to a range from 60% to 100% of an original size. At 2 sites, the skin grafts had stretched from 110% to 130% of the original size. This strategy may be useful for the treatment of burn scar contracture in children.
-
Since mechanical retractors in endoscopic plastic surgery cause certain drawbacks, we developed a model in dogs, which, by insufflating CO2 into a subcutaneous cavity, we were able to maintain. We evaluated the magnitude of subcutaneous emphysema and absorption of CO2 by insufflating different pressures and the efficacy of external pressure on the skin with the purpose of limiting the subcutaneous emphysema. Sixteen dogs were divided in 3 groups, A, B, and C. We controlled the pulmonary function by using a volume-cycle ventilator. In all groups, we maintained a subcutaneous cavity by insufflating CO2. Groups A and C were insufflated at 15 mm Hg; group B, at 8 mm Hg. We placed circumferential Esmarch bandages on the thorax of groups B and C to delimit superiorly and inferiorly the surgical area. Arterial blood gas analyses (ABGA) were taken from the femoral artery 60 minutes after intubation, 60 minutes after Esmarch bandage was placed and at the end of the CO2 insufflation. Statistically, results were analyzed by Wilcoxon test. P < 0.05 was considered statistically significant. Group A showed extensive subcutaneous emphysema. Two dogs died. The systemic increase of the CO2 showed a median of 9.6 mm Hg (P < 0.05). In Group B, Esmarch bandages caused increase in CO2, with a median of 1.65 mm Hg (P < 0.028). None of these dogs showed subcutaneous emphysema during the insufflation after CO2 insufflation pressure augmented with a median of 3.7 mm Hg (P < 0.028). In Group C, chest restriction increased CO2 median of 6.1 mm Hg (P < 0.043), and subcutaneous emphysema shown was less extensive than group A. The CO2 increased after insufflation a median of 16 mm Hg (P < 0.043). ⋯ Subcutaneous cavities can be maintained open with CO2 insufflation at 8 mm Hg, limiting perfectly the surgical area; as done with Esmarch bandages, it reduces CO2 absorption and makes this procedure safe.
-
Annals of plastic surgery · Jul 2006
An alternative dressing material for the split-thickness skin graft donor site: oxidized regenerated cellulose.
The split-thickness skin graft (STSG) donor sites have been treated with various and plenty of dressing techniques and materials. An ideal STSG donor site dressing should have antibacterial, hemostatic, and promoting epidermal healing properties. We have performed a prospective study to evaluate the effect of the oxidized regenerated cellulose on STSG donor site healing. ⋯ There was a statistical significance between the oxidized regenerated cellulose side and the fine mesh gauze side (P < 0.001) in group I and group II separately. The difference between group I and group II was statistically significant in the oxidized regenerated cellulose side (P < 0.001), and the difference between group I and group II was statistically significant in the fine mesh gauze side (P < 0.005). The antibacterial, hemostatic, and absorbable property of the oxidized regenerated cellulose could ensure the utilization as an alternative STSG donor site dressing, especially because the positive influence over the wound healing was proven.
-
Annals of plastic surgery · Jul 2006
Hand knife versus powered dermatome: current opinions, practices, and evidence.
Some surgeons prefer to use powered dermatomes when harvesting split-thickness skin grafts, while others prefer the hand knife. We conducted a postal survey of British plastic surgery units, contacted medicolegal departments, and investigated the literature to explore the reasoning for any preferences and the existing evidence to support such practices. ⋯ We found no evidence to support such clinical or medicolegal views and conclude that numerous misconceptions exist about skin-graft harvesting instruments. We suggest that surgeons should use whichever instrument they feel will, in their hands, provide the optimum result and not be directed by unfounded opinions.
-
Annals of plastic surgery · Jul 2006
Electrosurgery in patients with pacemakers/implanted cardioverter defibrillators.
Despite improved protective mechanisms, pacemakers and implanted cardioverter defibrillators are subject to interference from various sources. An effective means of hemostasis, electrocautery generates electromagnetic interference and may be problematic in this patient population. ⋯ Recommendations regarding the management of patients with implanted cardiac devices become increasingly significant both as the number of patients with devices increases and the number of out-of-hospital/minor surgery procedures performed increases. This article provides surgeons and anesthetists with practical recommendations for use of electrocautery in patients with pacemakers or implantable cardiac defibrillators.