Orthopedics
-
Using Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty Necessitating 44- or 46-mm Metal Shells.
Ceramic-on-ceramic articulation shows the lowest wear, with a low incidence of osteolysis. A small cup limits options regarding liner thickness and femoral implant size. The purpose of this study was to evaluate the safety of a 4-mm-thick ceramic liner and the outcomes of cementless total hip arthroplasty using a 44- or 46-mm metal shell and a ceramic-on-ceramic bearing at mid- to long-term follow-up. ⋯ Two hips underwent revision because of periprosthetic fractures. The survival rates of the acetabular cups and the femoral stems were 100% and 97.4%, respectively. The thin (4 mm) ceramic liner did not increase the risk of ceramic fracture and did not affect the mid- to long-term results and survival of cementless total hip arthroplasty using 44- or 46-mm metal shells. [Orthopedics. 2018; 41(3):e354-e359.].
-
Comparative Study
Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.
Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. ⋯ The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.].
-
Aspirin and unfractionated heparin (UH) are accepted options for venous thromboembolism (VTE) prophylaxis after total joint arthroplasty (TJA). The use of aspirin in addition to UH in preventing VTE after TJA has yet to be studied. The primary objective of this study was to determine VTE rates in patients receiving aspirin monotherapy and those receiving aspirin and UH combination therapy immediately following TJA. ⋯ Aspirin and UH combination therapy did not decrease VTE incidence compared with aspirin monotherapy. Additionally, there was greater perioperative blood loss and an increased rate of blood transfusion in patients receiving UH. On the basis of these findings, the authors do not recommend UH as an additional mode of VTE prophylaxis when prescribing aspirin after elective TJA. [Orthopedics. 2018; 41(3):171-176.].
-
The objective of this investigation was to examine the characteristics that place patients at risk for unanticipated inpatient admission after outpatient arthroscopic rotator cuff repair. This retrospective cohort study used the American College of Surgeons National Surgical Quality Improvement Program data sets from years 2012 to 2015. Patients were included in the study based on the presence of a primary Current Procedural Terminology code for rotator cuff repair (23410, 23412, 23420, and 29827). ⋯ The primary outcome variable was admission after outpatient surgery (defined as length of initial hospital stay >0). This study examined risk factors for unanticipated admission following rotator cuff repair, finding that age of 65 years or older, female sex, hypertension, body mass index of 35 kg/m2 or greater, American Society of Anesthesiologists classification of 2 or greater, and open surgical technique were significant predictors of admission, whereas monitored anesthesia care and regional anesthesia were associated with decreased odds of admission. Identifying patients with these characteristics will be critical in risk adjusting the anticipated cost of the episode of care in outpatient rotator cuff repair. [Orthopedics. 2018; 41(3):164-168.].