Sleep
-
We measured respiratory mechanical characteristics during sleep in five heavy, nonapneic snorers (HS) and in five obstructive sleep apnea (OSA) patients. In two HS and in two OSA patients we obtained lateral pharyngeal cineradiographic images during sleep while snoring. Flow limitation preceded all snores in both HS and OSA. ⋯ Maximal flow during snoring was less (p less than 0.05) in OSA (0.18 +/- 0.07 liter/second) than in HS (0.36 +/- 0.06 liter/second). Linear supraglottic resistance during inspiratory snoring was higher, though not significantly, in OSA patients (7.11 +/- 3.01 cm H2O/liter/second) than in HS (4.80 +/- 2.83 cm H2O/liter/second). We conclude that: 1) Snoring is characterized by high frequency oscillations of the soft palate, pharyngeal walls, epiglottis and tongue. 2) Flow limitation appears to be a sine qua non for snoring during sleep. 3) The pattern of snoring is different in OSA and HS. 4) Pharyngeal size during snoring is probably larger in HS than in OSA patients.