A randomized crossover efficacy trial of oral CPAP (Oracle) compared with nasal CPAP in the management of obstructive sleep apnea.
To determine the therapeutic efficacy and viability of a novel oral interface for continuous positive airway pressure (CPAP) compared with conventional nasal interfaces. ⋯ This preliminary study indicates that oral CPAP has similar efficacy to traditionally applied nasal CPAP in treating obstructive sleep apnea. Additional large studies are required to determine the range of clinical situations where oral CPAP is indicated.
-
Assess objectively measured sleep quality in premenopausal, perimenopausal, and postmenopausal women. ⋯ Menopause is not associated with diminished sleep quality measured by polysomnography. Although perimenopausal and postmenopausal women, relative to premenopausal women, were less satisfied with their sleep, menopause was not a strong predictor of specific sleep-disorder symptoms. Symptoms and signs of sleep abnormalities in midlife women should not be attributed primarily to menopause before ruling out underlying sleep disorders.
-
To use near-infrared spectroscopy to investigate the effect of obstructive sleep apnea on cytochrome oxidase, the terminal enzyme of the mitochondrial respiratory chain. ⋯ Changes in directly measured cerebral tissue saturation and changes in arterial saturation and cerebral blood flow velocity (the 2 main factors affecting cerebral oxygenation) are associated with changes in cytochrome-oxidase oxidation state. The reduced cerebral oxygenation that occurs during obstructive sleep apnea is associated with changes in the intracellular redox state.
-
The following hypotheses were investigated: 1) severe obstructive sleep apnea (OSA) can mask concurrent periodic limb movement (PLM) disorder (PLMD), which becomes evident or worsens after treatment with continuous positive airway pressure (CPAP); 2) in patients with mild OSA, PLMs are not masked but may be triggered by subclinical hypopneas or respiratory effort-related arousals and improve after CPAP. ⋯ Severity of OSA may determine the effect of CPAP on PLMs. The PLMs may increase in moderate to severe OSA due mainly to "unmasking" of underlying PLMD. The PLMs may decrease in mild OSA post-CPAP due to resolution of PLMs associated with respiratory effort-related arousals. This suggests that PLMs may have more than 1 etiology and may be categorized as spontaneous (as in PLMD) and induced (when secondary to respiratory effort-related arousals).