Hearing research
-
Hearing-in-noise (HIN) is a primary complaint of both the hearing impaired and the hearing aid user. Both auditory nerve (AN) function and outer hair cell (OHC) function are thought to contribute to HIN, but their relative contributions are still being elucidated. OHCs play a critical role in HIN by fine tuning the motion of the basilar membrane. Further, animal studies suggest that cochlear (auditory) synaptopathy, which is the loss of synaptic contact between hair cells and the AN, may be another cause of HIN difficulty. While there is evidence that cochlear synaptopathy occurs in animal models, there is debate as to whether cochlear synaptopathy is clinically significant in humans, which may be due to disparate methods of measuring noise exposure in humans and our high variability in susceptibility to noise damage. Rather than use self-reported noise exposure to define synaptopathic groups, this paper assumes that the general population exhibits a range of noise exposures and resulting otopathologies and defines cochlear synaptopathy "operationally" as low CAP amplitude accompanied by normal DPOAE levels in persons with low pure tone averages. The first question is whether the standard audiogram detects AN dysfunction and OHC dysfunction? The second question is whether HIN performance is primarily dependent on AN function, OHC function, or both functions? ⋯ The results of this study suggest the following: (1) persons hearing within normal limits may exhibit HIN difficulties; (2) persons hearing within normal limits may exhibit undetected otopathologies, namely AN dysfunction and OHC dysfunction; (3) AN untuning secondary to OHC dysfunction occurs in subjects with Mild-Moderate SNHL; (4) HIN performance is primarily governed by OHC function rather than AN function.
-
Hyperacusis is a debilitating hearing condition in which normal everyday sounds are perceived as exceedingly loud, annoying, aversive or even painful. The prevalence of hyperacusis approaches 10%, making it an important, but understudied medical condition. To noninvasively identify the neural correlates of hyperacusis in an animal model, we used sound-evoked functional magnetic resonance imaging (fMRI) to locate regions of abnormal activity in the central nervous system of rats with behavioral evidence of hyperacusis induced with an ototoxic drug (sodium salicylate, 250 mg/kg, i.p.). ⋯ To confirm the main results, electrophysiological recordings of spike discharges from multi-unit clusters were obtained from the central auditory pathway. Salicylate significantly enhanced tone-evoked spike-discharges from multi-unit clusters in the AC from 4 to 30 kHz at intensities ≥60 dB SPL; less enhancement occurred in the medial geniculate body (MGB), and even less in the IC. Our results demonstrate for the first time that non-invasive sound-evoked fMRI can be used to identify regions of neural hyperactivity throughout the brain in an animal model of hyperacusis.
-
Comparative Study
Paired measurements of cochlear function and hair cell count in Dutch-belted rabbits with noise-induced hearing loss.
The effects of noise-induced hearing loss have yet to be studied for the Dutch-belted strain of rabbits, which is the only strain that has been used in studies of the central auditory system. We measured auditory brainstem responses (ABRs), 2f1-f2 distortion product otoacoustic emissions (DPOAEs), and counts of cochlear inner and outer hair cells (IHCs and OHCs, respectively) from confocal images of Myo7a-stained cochlear whole-mounts in unexposed and noise-overexposed, Dutch-belted, male and female rabbits in order to characterize cochlear function and structure under normal-hearing and hearing-loss conditions. Using an octave-band noise exposure centered at 750 Hz presented under isoflurane anesthesia, we found that a sound level of 133 dB SPL for 60 min was minimally sufficient to produce permanent ABR threshold shifts. ⋯ We paired post-exposure ABR and DPOAE threshold shift data with hair cell count data measured in the same ear at the same frequency and cochlear frequency location. ABR and DPOAE threshold shifts exhibited critical values of 46 and 18 dB, respectively, below which the majority of OHCs and IHCs survived and above which OHCs were wiped out while IHC survival was variable. Our data may be of use to researchers who wish to use Dutch-belted rabbits as a model for the effects of noise-induced hearing loss on the central auditory system.
-
The electrically-evoked compound action potential (ECAP) is correlated with spiral ganglion neuron (SGN) density in cochlear implanted animals. In a previous study, we showed that ECAP amplitude growth function (AGF) linear slopes for stimuli with a constant interphase gap (IPG) changed significantly over time following implantation. Related studies have also shown that 1) IPG sensitivity for ECAP measures ("IPG Effect") is related to SGN density in animals and 2) the ECAP IPG Effect is related to speech recognition performance in humans with cochlear implants. ⋯ Post-implantation changes in ECAPs and impedances were not correlated with one another. Results from this study are helpful for estimating the mechanisms underlying ECAP characteristics and have implications for clinical application of the ECAP measures in long-term human cochlear implant recipients. Specifically, these measures could help to monitor neural health over a period of time, or during a time of stability these measures could be used to help select electrode sites for activation in clinical programming.
-
Electrically evoked compound action potentials (eCAPs) are measurements of the auditory nerve's response to electrical stimulation. ECAP amplitudes during pulse trains can exhibit temporal alternations. The magnitude of this alternation tends to diminish over time during the stimulus. ⋯ In addition, the peak alternation was affected by changing the refractoriness, adaptation, and relative spread of auditory nerve fibers. As these parameters are related to factors such as the duration of deafness and neural survival, this study suggests that the eCAP pattern in response to pulse trains could be used to assess the underlying temporal and stochastic behavior of the auditory nerve. As these properties affect the nerve's response to pulse trains, they are of uttermost importance to sound perception with cochlear implants.