Clinical cardiology
-
Clinical cardiology · Jul 2014
Multicenter StudyFrom door-to-balloon time to contact-to-device time: predictors of achieving target times in patients with ST-elevation myocardial infarction.
The 2013 American College of Cardiology Foundation/American Heart Association ST-segment elevation myocardial infarction (STEMI) guidelines have shifted focus from door-to-balloon (D2B) time to the time from first medical contact to device activation (contact-to-device time [C2D] ). ⋯ In STEMI patients, PHT was associated with significantly reduced C2D and D2B times and was an independent predictor of achieving a target C2D time. As centers adapt to the new guidelines emphasizing C2D time, targeting a shorter D2B time (<50 minutes) is ideal to achieve a C2D time of <90 minutes.