Cardiovascular and interventional radiology
-
Cardiovasc Intervent Radiol · Jul 2009
Placement of hemodialysis catheters through stenotic or occluded central thoracic veins.
A method for hemodialysis catheter placement in patients with central thoracic venous stenosis or occlusion is described and initial results are analyzed. Twelve patients, with a mean age of 63.2 years (42-80 years), with central venous stenosis or occlusion, and who required a hemodialysis catheter were reviewed. All lesions were confirmed by helical CT or phlebography. ⋯ Two were successfully managed by percutaneous endovascular approach and one catheter was removed. In conclusion, for patients with central venous stenosis or occlusion and those who need a hemodialysis catheter, catheter insertion can be reliably achieved immediately after endovascular recannalization with acceptable technical and long-term success rates. This technique should be considered as an alternative procedure for placing a new hemodialysis catheter through a patent vein.
-
Cardiovasc Intervent Radiol · Jul 2009
A survey of interventional radiology awareness among final-year medical students in a European country.
Interventional radiology (IR) is a rapidly expanding specialty that is facing the challenges of turf wars and personnel shortages. Appropriate exposure of medical students to this field can be vital to recruitment of potential future trainees or referring physicians. The aim of this study was to determine the knowledge and views of final-year medical students in a single EU country regarding various aspects of IR. ⋯ A significant number of students (76%) thought that the job prospects in IR are good or excellent but only 40.5% were willing to consider a career in IR. In conclusion, this study indicates that IR remains a nascent but attractive specialty to the majority of medical students. Further development of the existing informal undergraduate curriculum to address shortcomings will ensure that IR continues to attract the brightest talents to the field.
-
Cardiovasc Intervent Radiol · Jul 2009
Case ReportsEndovascular repair of a right-sided descending thoracic aortic aneurysm associated with a right aortic arch and a left subclavian artery arising from a Kommerell's diverticulum.
This case report describes the endovascular repair of a right-sided descending thoracic aortic aneurysm associated with a right aortic arch and an aberrant left subclavian artery. A 76-year-old male with multiple comorbidities was incidentally found to have a right-sided descending thoracic aortic aneurysm with a maximum diameter of 6.2 cm. Additionally, there was a right aortic arch with a retroesophageal segment and separate arch branches arising in the following order: left common carotid artery, right common carotid artery, right subclavian artery, and left subclavian artery that was aberrant, arising from a Kommerrell's diverticulum. ⋯ At 18-month follow-up the patient was doing well, with aneurysm sac shrinkage to 5.9 cm and no signs of endoleak or migration. Endovascular repair of right-sided descending thoracic aortic aneurysms with a right arch and aberrant left subclavian artery is feasible, safe, and effective. In such rare configurations, which demand considerably increased technical dexterity and center experience, endovascular repair emerges as an attractive therapeutic option.
-
Cardiovasc Intervent Radiol · May 2009
First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. ⋯ Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
-
Cardiovasc Intervent Radiol · May 2009
Letter Case ReportsStent-graft repair of a large cervical internal carotid artery pseudoaneurysm causing dysphagia.
Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.