Biomaterials
-
Effective treatment options are often limited for implant-associated orthopedic infections. In this study we evaluated the antimicrobial effects of applying cathodic voltage-controlled electrical stimulation (CVCES) of -1.8 V (vs. Ag/AgCl) to commercially pure titanium (cpTi) substrates with preformed biofilm-like structures of methicillin-resistant Staphylococcus aureus (MRSA). ⋯ The stimulation was not associated with histological changes in the host tissue surrounding the implant. As compared to the OCP conditions, the -1.8 V stimulation significantly increased the interfacial capacitance (18.93 vs. 98.25 μF/cm(2)) and decreased polarization resistance (868,250 vs. 108 Ω-cm(2)) of the cpTi. The antimicrobial effects are thought to be associated with these voltage-dependent electrochemical surface properties of the cpTi.