Veterinary surgery : VS
-
Veterinary surgery : VS · Sep 1987
Comparative StudySurgical management of proximal splint bone fractures in the horse.
Fractures of Metacarpal and Metatarsal II and IV (the splint bones) were treated in 283 horses over an 11 year period. In 21 cases the proximal portion of the fractured bone was stabilized with metallic implants. One or more cortical bone screws were used in 11 horses, and bone plates were applied in 11 horses. ⋯ Complications of plate fixation included partial fixation failure (backing out of screws), wound drainage, and proliferative bony response around the plate. Six of the 11 horses treated by plate fixation returned to their intended use. The authors recommend consideration of plate fixation techniques for repair of fractures in the proximal third of the splint bone.
-
Veterinary surgery : VS · May 1987
Case ReportsManagement of intractable pleural effusion in a dog with pleuroperitoneal shunt.
Persistent nonchylous pleural effusion followed thoracic duct ligation for chylothorax in a dog. Attempts at tetracycline pleurodesis twice failed to reduce the quantity of pleural effusion. Repeated thoracentesis caused malnutrition and hypoproteinemia. ⋯ Digital compression of the pump chamber alleviated the signs of respiratory compromise, without complication. At 50 weeks post-installation, a proteinaceous clot obstructed the original efferent pump valve, necessitating shunt replacement. Eight weeks after replacement, the dog was asymptomatic.