Nuclear medicine communications
-
Comparative Study
Is computer-aided interpretation of 99Tcm-HMPAO leukocyte scans better than the naked eye?
In order to compare visual interpretation of inflammation detected by leukocyte scintigraphy with that of different computer-aided quantification methods, 34 patients (25 with ulcerative colitis and 9 with endoscopically verified non-inflamed colonic mucosa), were investigated using 99Tcm-hexamethylpropyleneamine oxime (99Tcm-HMPAO) leukocyte scintigraphy and colonoscopy with biopsies. Scintigrams were obtained 45 min and 4 h after the injection of labelled cells. Computer-generated grading of seven colon segments using four different methods was performed on each scintigram for each patient. ⋯ Agreement assessed using kappa statistics was 0.54 at 45 min (P < 0.001). Separate data concerning the presence/absence of active inflammation showed a high kappa value (0.74, P < 0.001). Our results showed that a simple scintigraphic scoring system based on assessment using the human eye reflects colonic inflammation at least as well as computer-aided grading, and that highly correlated results can be achieved between different investigators.