Texas Heart Institute journal
-
Left ventricular assist device (LVAD)-supported patients are evaluated routinely with use of transthoracic echocardiography. Values of left ventricular unloading in this unique patient population are needed to evaluate LVAD function and assist in patient follow-up. We introduce a new M-mode measurement, the slope of the anterior mitral valve leaflet (SLAM), and compare its efficacy with that of other standard echocardiographically evaluated values for left ventricular loading, including E/e' and pulmonary artery systolic pressures. ⋯ In addition, a cutpoint of 10 cm/s distinguished random patients with LVEF <0.35 from those in end-stage congestive heart failure (pre-LVAD) with an 88% sensitivity and a 55% specificity. Evaluating ventricular unloading in LVAD patients remains challenging. Our novel M-mode value correlates with echocardiographic values of left ventricular filling in patients with moderate-to-severe systolic function and dynamically improves with the ventricular unloading of an LVAD.
-
A 42-year-old man emergently presented with chest pain and anterior ST elevation. Refractory ventricular arrhythmias and shock developed rapidly. ⋯ The electrocardiographic pattern was a result of isolated right ventricular infarction that in turn caused profound electrical and hemodynamic instability. We discuss the cause and pathophysiology of this patient's case, and we recommend that interventional and general cardiologists be aware that anterior ST elevation can be caused by the occlusion of a nondominant right coronary artery.