Heart & lung : the journal of critical care
-
Patients undergoing cardiac surgery are mildly hypothermic by the completion of the surgical procedure. They need to return to a normothermic state if enzymatic functions are to proceed in their normal manner. The body can produce heat by elevating metabolic rate or by activating the shivering mechanism. ⋯ External methods, which minimize additional heat loss, include the use of warming lights, elevation of room temperature, and the use of blankets. Internal methods, which transfer heat by convection, may be used to help actively reverse hypothermia. Such techniques include warmed inhalation gases and intravenous fluids, warmed nasogastric lavage fluid, and warmed peritoneal dialysis fluid for patients with end-stage renal failure with severe electrolyte disorders after surgery.
-
Clinical Trial Controlled Clinical Trial
Patient-controlled analgesia versus intermittent analgesia dosing.
Actively involving the patient in his or her own pain management by using patient-controlled analgesia (PCA) during the postoperative period is a concept recently introduced. This method allows self-administration of small, frequent doses of an analgesic agent to maintain a state of constant pain control. We studied the relative efficacy of PCA compared with intermittent analgesic dosing in 16 male patients requiring posterolateral thoracotomy. ⋯ In the patients using PCA, a significant reduction in the postoperative pulmonary complication rate, as evidenced by radiographic findings, was noted. In addition, significantly less medication was used and postoperative fever was substantially reduced in the PCA group. We believe PCA to be a safe, effective, and beneficial pain management modality that deserves attention in the postoperative period.
-
Our purpose in this study was to investigate the factors coincident with the occurrence of dyspnea in ventilator-assisted patients. Five alert and oriented patients with pulmonary disease that was restrictive, obstructive, or both, who were receiving mechanical ventilation, participated in this descriptive study. ⋯ A moderate correlation (r = 0.51, p less than 0.001) was found between the number of events and activities occurring in the intensive care unit environment and the occurrence and severity of dyspnea. The visual analogue scale and modified Borg scale measures of dyspnea were highly correlated (r = 0.92, p less than 0.001) and may be useful tools for assessing dyspnea in patients undergoing mechanical ventilation.
-
With positive end-expiratory pressure (PEEP)-induced reduction in cardiac output, measurement of ventricular filling pressure assists in proper therapeutic decision-making. Because PEEP may increase pleural and juxtacardiac pressure, central venous pressure (CVP) and left atrial pressure (LAP) measurements during PEEP may not simply reflect ventricular filling, but rather reflect the sum of intracardiac and extracardiac forces. Monitoring devices placed within the central circulation use saline solution-filled lumens and transducer systems for pressure monitoring. ⋯ In the present study, esophageal pressure (Pes) was measured with a saline solution-filled balloon-equipped nasogastric tube to estimate the extracardiac influence of PEEP on CVP and LAP. Pes, CVP, LAP, and cardiac index (CI) were measured in 17 patients subjected to 0, 5, 10, 15, 20 cm H2O PEEP. Comparing 0 with 20 cm H2O PEEP, CVP (7 +/- 1.0 mm Hg to 13.4 +/- 1.3 mm Hg), LAP (6.3 +/- 1.1 mm Hg to 11.7 +/- 1.4 mm Hg), and Pes (6.1 +/- 1.4 mm Hg to 12.1 +/- 1.5 mm Hg) all increased significantly as CI fell (2.72 +/- 0.14 L/min/m2 to 2.20 +/- 0.15 L/min/m2).(ABSTRACT TRUNCATED AT 250 WORDS)
-
Closed system suctioning (CSS) is a method of removing secretions from the tracheobronchial tree of patients with mechanical ventilation without disconnecting the mechanical ventilator. The putative benefits of CSS include the maintenance of positive pressure ventilation, oxygen supply, and positive end-expiratory pressure (PEEP). However, some evidence indicates that negative airway pressure may develop during CSS if inappropriate ventilator settings are selected. ⋯ During each suctioning trial, the peak positive and negative airway pressures were recorded. The negative airway pressure was above -10 cm H2O in most situations. In the control mode at all flow rates with or without PEEP, the Bennett MA1 and the Bourns-Bear 1 and 2 produced sustained peak negative airway pressure of less than -50 cm H2O.(ABSTRACT TRUNCATED AT 250 WORDS)