The Science of the total environment
-
Sci. Total Environ. · Sep 2007
Non-positive autoimmune responses against CYP2E1 in refrigeration mechanics exposed to halogenated hydrocarbons.
The aim of the study was to determine if occupational exposure to hydrofluorocarbons (HFC) and hydrochlorofluorocarbons (HCFC) generates autoimmune responses against CYP2E1. HFCs and HCFCs have replaced the chlorofluorocarbons (CFC) in e.g. refrigeration installations and air-conditioning systems. During the substitution period, refrigeration mechanics reported symptoms like asthma, influenza-like reactions, and joint troubles. ⋯ No increase in autoantibodies against CYP2E1 was detected among the occupationally exposed workers as compared to the unexposed controls. Further, there was no difference in antibody titer between the exposed workers with symptoms and the exposed, asymtomatic workers or the unexposed controls. The present study does not completely exclude a connection between exposure and effect but makes the relation less likely at these exposure levels.