Improvement of a stability-indicating method by Quality-by-Design versus Quality-by-Testing: a case of a learning process.
The understanding of the method is a major concern when developing a stability-indicating method and even more so when dealing with impurity assays from complex matrices. In the presented case study, a Quality-by-Design approach was applied in order to optimize a routinely used method. An analytical issue occurring at the last stage of a long-term stability study involving unexpected impurities perturbing the monitoring of characterized impurities needed to be resolved. ⋯ The selected working condition was then fully validated using accuracy profiles based on statistical tolerance intervals in order to evaluate the reliability of the results generated by this LC/ESI-MS stability-indicating method. A comparison was made between the traditional Quality-by-Testing (QbT) approach and the QbD strategy, highlighting the benefit of this QbD strategy in the case of an unexpected impurities issue. On this basis, the advantages of a systematic use of the QbD methodology were discussed.
-
J Pharm Biomed Anal · Jan 2014
Development and application of a UPLC-MS/MS method for the pharmacokinetic study of 10-hydroxy camptothecin and hydroxyethyl starch conjugate in rats.
With the purpose to carry out the pharmacokinetic studies of 10-hydroxy camptothecin (10-HCPT) and hydroxyethyl starch (10-HCPT-HES) conjugate, an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated. The analytes, 10-HCPT and the internal standard, Diphenhydramine hydrochloride were extracted with ethyl acetate-isopropanol (95:5, v/v) and separated on an ACQUITY UPLC™ BEH C18 column using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) with a linear gradient program. With positive ion electrospray ionization (ESI), the analytes were monitored on a triple quadrupole mass spectrometer in the multiple reaction monitoring (MRM) mode. ⋯ Commercial 10-HCPT injection and 10-HCPT-HES conjugate were administered intravenously at an equal dose of 10-HCPT at 0.5mg/kg. The biological half-life of conjugate was increased significantly from 10min to 3.15h and the bioavailability was 40 times higher than 10-HCPT injection. Consequently, the proposed UPLC-ESI-MS/MS method was proved to be sensitive, specific and reliable to analyze 10-HCPT in biological samples; 10-HCPT and HES conjugate is a promising strategy for delivery of 10-HCPT with prolonged half time and improved bioavailability.
-
J Pharm Biomed Anal · Jan 2014
Liquid chromatography-tandem mass spectrometric assay for the cyclin-dependent kinase inhibitor AT7519 in mouse plasma.
A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for the cyclin-dependent kinase inhibitor AT7519 in mouse plasma was developed and validated. Plasma samples were pre-treated using protein precipitation with acetonitrile containing rucaparib as internal standard. After dilution with water, the extract was directly injected into the reversed-phase LC system. ⋯ Accuracies were between 95.9 and 99.0% for the whole calibration range. The drug was stable under all relevant analytical conditions. Finally, the assay was successfully used to determine plasma pharmacokinetics after intraperitoneal administration of AT7519 in mice with neuroblastoma xenografts.