IEEE transactions on medical imaging
-
IEEE Trans Med Imaging · May 2014
An analysis of whole body tracer kinetics in dynamic PET studies with application to image-based blood input function extraction.
In a positron emission tomography (PET) study, the local uptake of the tracer is dependent on vascular delivery and retention. For dynamic studies the measured uptake time-course information can be best interpreted when knowledge of the time-course of tracer in the blood is available. This is certainly true for the most established tracers such as 18F-Fluorodeoxyglucose (FDG) and 15O-Water (H2O). ⋯ A collection of arterially sampled data from PET studies with FDG and H2O is used to illustrate the methodology. These data analyses are highly supportive of the overall modeling approach. An adaptation of the model to the problem of extraction of arterial blood signals from imaging data is also developed and promising preliminary results for cerebral and thoracic imaging studies with FDG and H2O are obtained.