Journal of orthopaedic research : official publication of the Orthopaedic Research Society
-
The torque-angular deformation in right axial rotation until failure of the ligamentous occipito-atlanto-axial complex subjected to variable loading rate (dynamic) axial torque was characterized using a biaxial MTS system. A special fixture and gear box that permitted right axial rotation of the specimen until failure without imposing any additional constraints were used to obtain the data. The specimens were divided into three groups and tested until failure at three different dynamic loading rates: 50, 100, and 400 degrees/s. ⋯ The average maximum resistance torque increased from 13.6 Nm at 4 degrees/s to 27.8 Nm at 100 degrees/s. The corresponding right angular rotation data (65-78 degrees), however, did not show any significant variation with loading rate. Posttest dissection of the specimens indicated that the type of injury observed was related to the rate of axial loading imposed on a specimen during testing.(ABSTRACT TRUNCATED AT 250 WORDS)