Journal of orthopaedic research : official publication of the Orthopaedic Research Society
-
Developing spinal pathologies and spinal fusion after total hip arthroplasty (THA) can result in increased pelvic retroversion (e.g., flat back deformity) or increased anterior pelvic tilt (caused by spinal stenosis, spinal fusion or other pathologies) while bending forward. This change in sagittal pelvic tilt (SPT) can result in prosthetic impingement and dislocation. Our aim was to determine the magnitude of SPT change that could lead to prosthetic impingement. ⋯ Femoral stems with a higher neck-shaft angle decrease the prosthetic impingement due to SPT change in motions requiring hip flexion (OR: 1.16 [132° stem]; OR: 4.94 [135° stem]). Our results show that overall, the risk of prosthetic impingement due to SPT change is low. In particular, this risk is very low when a larger diameter head is used and femoral offset and length are recreated to prevent bone on bone impingement.