Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
-
The effectiveness of ABC has been traditionally measured as the reduction in internal margin (IM) within the planning target volume (PTV). Not to overestimate the benefit of ABC, the effect of patient movement during treatment also needs to be taken into account. We determined the IM and set-up error with ABC and the effect on physical lung parameters compared to standard margins used with free breathing. We also assessed interfraction oesophageal movement to determine a planning organ at risk volume (PRV). ⋯ The reduction in PTV size with ABC resulted in an 18-25% relative reduction in physical lung parameters. PTV margin reduction has the potential to spare normal lung and allow dose-escalation if coupled with image-guided RT. The oesophageal PRV needs to be considered when irradiating central disease and is of increasing importance with altered RT fractionation and concomitant chemoradiation schedules. Further reductions in PTV and PRV may be possible if patient set-up error was minimised, confirming that attention to patient immobilisation is as important as attempts to control tumour motion.