Journal of vascular surgery
-
Clinical Trial
Fenestrated and branched endovascular aortic repair for chronic type B aortic dissection with thoracoabdominal aneurysms.
The treatment of patients with arch and thoracoabdominal aortic aneurysms (TAAAs) and chronic dissections is challenging. We report the results of fenestrated and branched endovascular aortic repair (FEVAR) of such aneurysms. ⋯ FEVAR is feasible for patients with chronic dissections and TAAA. Concerns regarding visceral vessel access and graft compression resulting from narrow true lumen diameters were not relevant in our experience. Favorable sac and lumen morphologic changes, coupled with a low mortality and complication risk, makes this an attractive means of handling this clinical problem.
-
Randomized Controlled Trial Comparative Study
Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.
Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. ⋯ Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique.
-
The precise relationship between risk factor burden and prevalence of peripheral artery disease (PAD) in different vascular territories (PAD, carotid artery stenosis [CAS], and abdominal aortic aneurysms [AAAs]) is unclear. ⋯ This very large contemporary database demonstrates that risk factor burden is associated with an increased prevalence of PVD, and there is a graded association between the number of risk factors present and the prevalence of PAD, CAS, and AAAs.
-
Multicenter Study Clinical Trial
Evaluation of the redesigned conformable GORE TAG thoracic endoprosthesis for traumatic aortic transection.
To evaluate the safety and effectiveness of the conformable GORE TAG thoracic endoprosthesis (CTAG) device (W. L. Gore and Associates, Flagstaff, Ariz) for the endovascular repair of traumatic aortic transections. ⋯ The CTAG device was demonstrated to be a safe and effective treatment for traumatic aortic transection based on 30-day outcomes. There were no device-related serious adverse events.
-
Comparative Study Clinical Trial
Radiation exposure to operating room personnel and patients during endovascular procedures.
To characterize radiation exposure to patients and operating room personnel during fluoroscopic procedures. ⋯ Personnel doses were best correlated with KAP and less well correlated with fluoroscopy time or CAK. The dosimeter on the anesthesia equipment recorded the highest doses attributable to ineffective shielding. Operators can reduce the effective dose to themselves, the patient, and other personnel by minimizing the use of digital subtraction acquisitions, avoiding lateral angulation, using higher magnification levels when possible, and being diligent about the use of shielding during fluoroscopy cases.