Journal of the American Podiatric Medical Association
-
J Am Podiatr Med Assoc · May 2013
Case ReportsIrreducible metatarsophalangeal joint dislocation of the lesser toes: a case report.
Irreducible metatarsophalangeal joint dislocation of the lesser toes is a rare injury. We present a 37-year-old man who was injured in a motorcycle accident and dislocated the first to third metatarsophalangeal joints and fractured the fourth metatarsal head. ⋯ Dislocation reduction was performed without damage to the plantar plate, and one Kirschner wire was used to fix the fourth metatarsal head fracture. The pin was removed 8 weeks after surgery, and the patient regained normal gait and returned to work and his previous physical activity level without recurrent dislocation.
-
J Am Podiatr Med Assoc · May 2013
Comparative StudyReliability and repeatability of the portable EPS-platform digital pressure-plate system.
Abnormal plantar pressures are the hallmark characteristic of several conditions and pathologic abnormalities. Pressure platforms allow for quick and accurate screening of patients and help guide clinical treatment. However, it is essential to evaluate the reliability and repeatability of these devices before making clinical decisions. The purpose of this study was to determine the reliability of the EPS-Platform during static and dynamic activities. ⋯ This study demonstrates that the EPS-Platform is a reliable device for collecting gait plantar pressures. Static trials produce better reliability, most likely owing to the large inherent variability during dynamic gait. Intersession reliability was higher than intrasession reliability owing to the intersession measures being calculated with an average of five trials. By averaging the trials, the variability of gait is decreased, and this improves the accuracy of the results. These results can be used as the basis for future studies and to determine a priori sample sizes for investigations that use the EPS-Platform.
-
J Am Podiatr Med Assoc · May 2013
Case ReportsOpen reduction-internal fixation of a navicular body fracture with dorsal displacement of the first and second cuneiforms: a case report.
Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. ⋯ After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.