Inhaled nitric oxide (iNO) is a potent and selective pulmonary vasodilator that decreases pulmonary resistance, and improves ventilation-perfusion matching, thereby improving oxygenation and reducing the need for more invasive therapies. Despite the efficacy of iNO at reducing the use of extracorporeal membrane oxygenation, significant concern remains over the potential toxicity from oxidative derivatives and methemoglobinemia. At present, there is no universal agreement on the lowest effective starting dose. Reported initial doses in the neonatal literature have ranged from 1 to 80 ppm. ⋯ There is significant variation in the starting dose of iNO between centers. Our retrospective study shows no evidence that higher doses improve outcome. A low concentration of iNO (<18 ppm) should be considered to minimize the potential toxicity of methemoglobin. Furthermore, a well-designed, prospective trial should be undertaken to further define the optimal starting dose.
-
To assess whether advances in neonatal care in the last decade have altered the outcome of very-low-birth-weight (VLBW) infants after cardiopulmonary resuscitation (CPR) in the neonatal intensive care unit (NICU). ⋯ Survival rate for the infants who require CPR in the NICU remains extremely poor. This poor outcome needs to be discussed with parents and the option of the "do not resuscitate" (DNR) order may be appropriate for these infants, especially for those infants with multiple organ failure unresponsive to therapy.
-
Necrotizing tracheobronchitis is a serious affection observed in ventilated newborns, frequently infants with instable hemodynamic state. It is characterized by acute episodes of airway obstruction. ⋯ The vascular theory seems to be of utmost importance in the physiopathology. Three cases are reported.
-
End tidal carbon monoxide levels are lower in women with gestational hypertension and pre-eclampsia.
The possible role of heme oxygenase and its byproduct carbon monoxide (CO) in the regulation of blood pressure is under investigation. The aim of this study was to compare end tidal breath CO (ETCO) levels in women with gestational hypertension (GH) or pre-eclampsia to the levels in healthy pregnant and nonpregnant women. ⋯ ETCOc levels were found to be significantly lower in women with GH/PE. Further investigation is required to determine if the lower CO levels reflect a deficient compensatory response to the increase in blood pressure or whether these are primary changes of significance to our understanding of the pathogenesis of GH/PE.
-
To study the impact of computerized physician order entry (CPOE) on selected neonatal intensive care unit (NICU) practices. ⋯ The implementation of CPOE in our NICU resulted in a significant reduction in medication turn-around times and medication errors for selected drugs, and a decrease in ancillary service (radiology) response time. In spite of the complexities of medication orders in pediatric populations, commercially available software programs for CPOE can successfully be adjusted to accommodate NICU needs and to beneficially impact clinical practice.