Spatial pattern of ventilation-perfusion mismatch following acute pulmonary thromboembolism in pigs.
We studied the spatial distribution of the abnormal ventilation-perfusion (Va/Q) units in a porcine model of acute pulmonary thromboembolism (APTE), using the fluorescent microsphere (FMS) technique. Four piglets ( approximately 22 kg) were anesthetized and ventilated with room air in the prone position. Each received approximately 20 g of preformed blood clots at time t = 0 min via a large-bore central venous catheter, until the mean pulmonary arterial pressure reached 2.5 times baseline. ⋯ Redistribution pattern was mostly seen in regional Q, whereas Va remained relatively unchanged. We concluded that the hypoxemia seen after APTE could be explained by the mechanical diversion of Q to the less embolized regions because of the vascular obstruction by clots elsewhere. These low Va/Q units created by high flow, rather than low Va, accounted for most of the resultant hypoxemia.
-
Comparative Study
Ultrasound: a reproducible method to measure conduit vein compliance.
Classical venous occlusion plethysmography (VOP) of the leg, often used to assess venous compliance, measures properties of the whole calf, including volume changes at the arterial side and the interstitial fluid accumulation that occurs as a result of the enhanced capillary pressure during venous occlusion. We present an ultrasound technique to measure the compliance of one major conduit vein in the leg. Ultrasound measurements of the popliteal vein were compared with classical VOP measurements, which were performed simultaneously in one subject. ⋯ Ultrasound provides reproducible measurements with short- and long-term coefficients of variation ranging from 10 to 15% for popliteal vein compliance and from 2 to 9% for absolute diameters at the different venous pressure steps. In addition, by using ultrasound, we were able to detect an 80% reduction in the compliance of the popliteal vein in SCI individuals compared with controls (P < 0.01). In conclusion, ultrasound is a suitable and reproducible method to measure conduit vein compliance and provides the possibility to specifically assess compliance of one vein instead of the whole calf.
-
Comparative Study
Pulmonary and extrapulmonary acute lung injury: inflammatory and ultrastructural analyses.
To test whether pulmonary and extrapulmonary acute lung injury (ALI) of identical mechanical compromise would express diverse morphological patterns and immunological pathways. For this purpose, a model of pulmonary (p) and extrapulmonary (exp) ALI with similar functional changes was developed and pulmonary morphology (light and electron microscopy), cytokines levels, and neutrophilic infiltration in the bronchoalveolar lavage fluid (BALF), elastic and collagen fiber content in the alveolar septa, and neutrophil apoptosis in the lung parenchyma were analyzed. BALB/c mice were divided into four groups. ⋯ Neutrophils in the BALF were more frequent in ALIp than in ALIexp. ALIp showed more extensive injury of alveolar epithelium, intact capillary endothelium, and apoptotic neutrophils, whereas the ALIexp group presented interstitial edema and intact type I and II cells and endothelial layer. In conclusion, given the same pulmonary mechanical dysfunction independently of the etiology of ALI, insult in pulmonary epithelium yielded more pronounced inflammatory responses, which induce ultrastructural morphological changes.