Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine
-
The clinical usefulness of the application of spin-echo diffusion-weighted imaging in the evaluation of extraaxial cysts and epidermoid tumors is demonstrated in a series of 15 patients. Apparent diffusion coefficient (ADC) images based on intravoxel incoherent motion (IVIM) were obtained with a maximum gradient b value = 100 s/mm2. Lesion ADC was qualitatively compared to external phantoms. ⋯ On the other hand, all cysts had ADC similar to the stationary water phantom. Lesion delineation was improved due to the replacement of normal pulsatile (very high ADC) cisternal CSF. Direct quantitative measurements of ADC using this technique may not be possible due to unavoidable motion artifact.
-
This contribution reports the first direct and noninvasive observation of cerebral glucose in normal anesthetized rats (n = 16) using short-echo-time localized proton NMR spectroscopy (2.35 T, STEAM, TR = 6000 ms, TE = 20 ms, 125 microliters). In addition to resonances from N-acetyl aspartate (NAA), glutamate, total creatine, cholines, taurine, and myoinositol, all spectra exhibit strongly coupled resonances from glucose (3.43, 3.80 ppm) that are readily identifiable using model solutions. The observed level of cerebral glucose in fasted rats covered a range of 15-40% of that of NAA giving absolute concentrations of 1.1-2.8 mM when NAA is taken to be 7 mM. The arterial blood glucose concentration was 7.7 +/- 0.8 mM in the same group of animals.