Non-2DFT k-space readout strategies are useful in fast imaging but prone to blurring when reconstructed off resonance. Field inhomogeneities or susceptibility variations, coupled with a long readout time, are the major sources of this artifact. Correction methods based on a priori off-resonance information such as an acquired field map have been proposed in the literature. ⋯ This paper introduces an improved algorithm for field map estimation which is both faster and more robust than the existing method. It uses a multi-stage estimation of the field map, starting from a coarse estimate both in frequency and space and proceeds towards higher resolution. The new algorithm is applied to phantom and in vivo images acquired with radial and spiral sequences to give sharper images.
-
A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the human brain are considerably increased compared with a conventional PRESS volume selection scheme. Thus proton spectra from J-coupled multiplet signals can be acquired with TE on the order of 20-30 ms avoiding the baseline problems arising at shorter echo times due to broad resonances. This allows to selectively acquire spectra from substances with longer T2 without the confounding effects from J-coupling occurring in conventional volume selection techniques.