The spin-echo response to visual activation was studied as a function of spatial resolution at a field of 1.5 T. The results showed that the increase in absolute T(2) upon activation was as large as 22.8 +/- 3.1% (P < 0.05) at the highest resolution (5.3 mm(3)), while it was as small as 3.5 +/- 0.2% (P < 0.05) at the lowest resolution (42.2 mm(3)). In addition, upon increasing resolution, the spin-echo signal decay as a function of echo time changed from monoexponential to nonexponential. ⋯ The data can be quantitatively accounted for using a model based on the intravascular origin of the spin-echo effect including both macrovascular and microvascular effects. Existing theories for the spin-echo BOLD effect based on diffusion through field gradients predict negligible spin-echo effects inside the large vessels and are therefore incompatible with the data. Magn Reson Med 42:617-626, 1999.