An implementation of fast spin echo at 4.7 T designed for versatile and time-efficient T(2)-weighted imaging of the human brain is presented. Reduced refocusing angles (alpha < 180 degrees) were employed to overcome specific absorption rate (SAR) constraints and their effects on image quality assessed. Image intensity and tissue contrast variations from heterogeneous RF transmit fields and incidental magnetization transfer effects were investigated at reduced refocusing angles. ⋯ Incidental magnetization transfer effects from multislice acquisitions were shown to attenuate white matter intensity by 25% and gray matter intensity by 15% at 180 degrees; less than 5% attenuation was seen in all tissues at flip angles below 60 degrees. We present multislice images acquired without excess delay time for SAR mitigation using a variety of protocols. Subsecond half Fourier acquisition single-shot turbo spin echo (HASTE) images were obtained with a novel variable refocusing angle echo train (20 degrees < alpha < 58 degrees) and high-resolution scans with a voxel volume of 0.18 mm(3) were acquired in 6.5 min with refocusing angles of 100 degrees.
-
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each excited slice against metal-induced field inhomogeneities. ⋯ By positioning all spins in a region-of-interest to their actual spatial locations, the through-plane distortions can be corrected by summing up the resolved spins in each voxel. The SEMAC technique does not require additional hardware and can be deployed to the large installed base of whole-body MRI systems. The efficacy of the SEMAC technique in eliminating metal-induced distortions with feasible scan times is validated in phantom and in vivo spine and knee studies.
-
Dynamic susceptibility contrast MRI (DSC-MRI) is the current standard for the measurement of Cerebral Blood Flow (CBF) and Cerebral Blood Volume (CBV), but it is not suitable for the measurement of Extraction Flow (EF) and may not allow for absolute quantification. The objective of this study was to develop and evaluate a methodology to measure CBF, CBV, and EF from T1-weighted dynamic contrast-enhanced MRI (DCE-MRI). A two-compartment modeling approach was developed, which applies both to tissues with an intact and with a broken Blood-Brain-Barrier (BBB). ⋯ The model provides a consistent description of tracer kinetics in all brain tissues, and an accurate assessment of perfusion and permeability in reference tissues. The measurement sequence requires optimization to improve CNR and the precision in the perfusion parameters. With this approach, DCE-MRI presents a promising alternative to DSC-MRI for quantitative bolus-tracking in the brain.
-
To improve the reproducibility of arterial input function (AIF) registration and absolute cerebral blood flow (CBF) quantification in dynamic-susceptibility MRI-perfusion (MRP) at 1.5T, we rescaled the AIF by use of a venous output function (VOF). We compared CBF estimates of 20 healthy, elderly volunteers, obtained by computed tomography (CT)-perfusion (CTP) and MRP on two consecutive days. ⋯ The rescaled MRP showed fair to moderate correlation with CTP for the central gray matter (GM) and the whole brain. Our results indicate that the method used for correction of partial volume effects (PVEs) improves MRP experiments by reducing AIF-introduced variance at 1.5T.